Augmented leads & the frontal axis: aVR, aVL, aVF

The Goldberger augmented leads add three more frontal-plane views. Together with I–III they make the hexaxial reference system used to read the QRS axis (normal −30° to +90°).

Focus leads: aVR aVL aVF
  • aVR (right shoulder): normally entirely NEGATIVE (P, QRS and T), it views the heart from the opposite side.
  • aVL and aVF are upright in the normal heart.
  • Frontal axis: normal −30° to +90°; a quick read is I and aVF both net-positive → normal axis.
The normal 12-lead. The focus leads are highlighted; the rest are dimmed:
Vent. rate 62 bpm PR interval 200 ms QRS dur 88 ms QT/QTc 416/423 ms P-QRS-T axes 87 63 69 SYNTHETIC 12-LEAD ECG for training only — not for diagnosis I aVR V1 V4 II aVL V2 V5 III aVF V3 V6 II · rhythm strip (10 s) 25 mm/s · 10 mm/mV · 0.05–150 Hz · ~50/60 Hz · 10 s